Approx. Rs 49,000 / PieceGet Latest Price
Product BrochureProduct Details:
Minimum Order Quantity | 1 Piece |
Conductivity Range | 1000 mS/cm |
Display Type | Digital Smart Display |
Features | 14 selectable ranges |
Warranty | 1 Year |
Mounting Type | Bottom, Back, Remote |
Process Connection Thread | TC End , Threaded, Hygienic |
- All-in-One conductivity sensor
- All wetted parts in PEEK
- Compact, food-safe, hygienic design
- 3-A sanitary standards and FDA-compliant, EHEDG-certified
- Available with HART® communication protocol
- Available with IO-Link communication interface
Performance characteristics conductivityConductivity
Min. measurable conductivity
Max. measuring span
Min. measuring span
Max. measuring error
- ± 1.0 % FSR , 0 … 1 mS/cm to 0 … 500 mS/cm
- ± 1.5 % FSR , 0 … 1000 mS/cm
- ± 1.5 % FSR , 0 … 500 µS/cm
Reference temperature25 °C , adjustableRepeatability
Compensated temperature range
Temperature compensation
- 0.0 … 5.0 % FSR/K , adjustable
Step response time, T90
Sample time
Performance characteristics concentrationConcentration
- Programmable with IO-Link and FlexProgram
Factory set media (available from FlexProgram)
- 0 … 25 % by weight , HNO3 (nitric acid)
- 36 … 82 % by weight , HNO3 (nitric acid)
- 0 12 % by weight , NaOH (caustic soda)
- 25 50 % by weight , NaOH (caustic soda)
Customer defined media
- Customer defined (30 point lookup table)
Performance characteristics temperatureTemperature
Measuring range
Thermal response time, T90
Max. measuring error
- ± 1.5 K
- 0.3 K , 20 … 50 °C
Process conditionsProcess temperature
- -20 … 140 °C , permanent
- 140 … 150 °C , max. t < 1 h
Process pressure
Process connectionConnection variants
Wetted parts material
Surface roughness wetted parts
HART® interfaceProperties
- Universal commands
- Common-practice commands
- Conductivity device family commands
- Device Specific Commands
- For more information please see ‚HART Field Device Specification‘
Protocol
IO-Link interfaceIO-Link version
Device profile
Baud rate
Cycle time
Process data length
SIO-mode
Process data (cyclic)
- Switch state
- Signal analog output 1
- Signal analog output 2
- Temperature
- Unit temperature
- Conductivity
- Concentration
- Actual measuring range
Ambient conditionsDegree of protection (EN 60529)
- IP67
- IP69K , with appropriate cable
Compliance and approvalsEMC
Hygiene
- 3-A (74-07)
- EHEDG EL Class I
- FDA (21 CFR 177.2415)
Safety